TA561-RTC - Real-time Clock Adaptor¶
Intended Purpose
The TA561-RTC real time clock adaptor is used for equipping AC500-eCo Processor Modules with a real-time clock.
The real time clock can be buffered via an optional standard lithium battery (CR2032) during power supply failures (see lithium battery for real-time clock of AC500-eCo Processor Modules CR2032 - Battery for Real-Time Clock).
Insertion and Replacement of the Adaptor
Warning
:strong:Risk of electric shock!
With an opened option cover, energized parts of the Processor Module could be touched.
- Always turn off and disconnect the power supply for the Processor Module before you open the option cover.
- Make sure that die option cover is closed before reconnecting the Processor Module to the power supply.
Insertion/ removal of the adaptor and replacement of the battery is also described in the installation instruction for TA561-RTC. See https://new.abb.com/products/ABB1SAP181400R0001
Click tab Documentation and select Operating Instruction.
The option cover is available as a spare part (see TA570 spare part set for AC500-eCo Processor Modules TA570 - Spare Part Set).
Replacement of the Battery
Warning
:strong:Risk of death by electric shock!
The terminals of the module can carry 240 V voltage.
Make sure that all voltage sources (supply and process voltage) are switched off before you begin with operations at the system.
Switch off power supply of the system and verify that the CPU is powerless.
- ⇒
LEDs (PWR, RUN, ERR) must be off.
Remove the option cover.
- ⇒
Remove the option cover of the CPU totally by pushing it to the outer side.
Attention
:strong:Avoidance of electrostatic charging
PLC devices and equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Observe the following rules when handling the system:
- Touch a grounded object to discharge potential static.
- Wear an approved grounding wrist strap.
- Do not touch connectors or pins on component boards.
- Do not touch circuit components inside the equipment.
- If available, use a static-safe workstation.
- When not in use, store the equipment in appropriate static-safe packaging.
Remove the option board.
- ⇒
Note
Remove SD Memory Card (if installed) / terminal block (COM2).
Remove the option board from the CPU by lifting it up with a screwdriver.
Remove the battery.
- ⇒
Note
:strong:ATTENTION!
Lithium batteries must not be recharged, not be disassembled and not be disposed of in fire.
Exhausted batteries must be recycled to respect the environment.
Dispose of battery properly according to disposal procedures for lithium batteries.
Insert replacement battery.
- ⇒
Note
:strong:ATTENTION!
A standard batterie CR2032 can be used for TA561-RTC and TA562-RS-RTC.
Nominal voltage: 3 V DC.
Required capacity: 230 mAh.
Required temperature range for discharge: 0 … +70 °C.
After replacement of the battery, the Real-time Clock (RTC) date and time must be set again by the user.
Don’t use a battery older than 3 years for replacement (e.g. battery kept too long in stock).
Batteries must be stored in a dry place.
Insert option board into the CPU.
- ⇒
Plug the adapter TA56x-RTC to the right expansion slot of the CPU.
Note
Make sure that the 2 noses of the expansion module fit to the holes of the CPU PCB.
See white circle in figure above.
Refit the option cover of the CPU.
- ⇒
Note
Remember to re-insert a SD Memory Card first if it has been removed previously.
Only now the CPU can connected to power.
Note
Set the time of the RTC.
Technical Data
RTC accuracy (at 25 °C) | Typ. ±2 s / 24 h |
Ordering Data
Order No. | Scope of delivery | Product life cycle status |
---|---|---|
1SAP 181 400 R0001 | TA561-RTC, Serial RTC adaptor for PM55x-xP and PM56x-xP | Active |
1TNE 968 901 R3200 | TA561-RTC, Serial RTC adaptor for PM55x-xP and PM56x-xP, Lithium battery included (available in China only) | Active |
Note
*) For planning and commissioning of new installations use modules in Active status only.