Channel Parameters for the Cam Switch (max. 32x)

Name Value Internal value Internal value, type Default
camToTrack0 *) Digital Output 0 … 7, none 0 … 7, FF BYTE FF
: : : : :
camToTrack31 Digital Output 0 .. .7, none 0 … 7, FF BYTE FF

*) The value of the parameter camToTrack#  defines which DO (digital output) is assigned to the track. camToTrack0 = 3 for example means that track 0 is assigned to the digital output 3. If the value FFh is set to a track, no digital output is assigned to it.

Name Value Referred FB from extended Cam Switch Library 2) Internal value Internal value, type

camType[0]

1)

Common

Pulsed

Timed

Comfort

Cam shift

Binary shift

Multiturn cam

Time timed

Reference

Multiturn timed

MCX_CamSwitchSimple_c

MCX_CamSwitchSimple_dc

MCX_PulseSwitch_dc

MCX_CamSwitchTimed_dc

MCX_CamSwitchComfort_dc

MCX_CamShift_dc

MCX_BinaryShift_dc

MCX_CamSwitchMulti_dc

MCX_SwitchTimeTimed_dc

MCX_BinaryReference_dc

MCX_CamSwitchMultiTimed_dc

0

1

2

3

4

5

6

7

8

9

BYTE

1) camType additionally to camToTrack identifies the type of each cam switch and enables the use of a specific Function Block from the Extended Cam Switch Library.

2) camType parameters and the Extended Camswitch Library: Extended Camswitch Library