Channel Parameters for the Cam Switch (max. 32x)¶
Name | Value | Internal value | Internal value, type | Default |
---|---|---|---|---|
camToTrack0 *) | Digital Output 0 … 7, none | 0 … 7, FF | BYTE | FF |
: | : | : | : | : |
camToTrack31 | Digital Output 0 .. .7, none | 0 … 7, FF | BYTE | FF |
*) The value of the parameter camToTrack# defines which DO (digital output) is assigned to the track. camToTrack0 = 3 for example means that track 0 is assigned to the digital output 3. If the value FFh is set to a track, no digital output is assigned to it.
Name | Value | Referred FB from extended Cam Switch Library 2) | Internal value | Internal value, type |
---|---|---|---|---|
camType[0] 1) … |
Common Pulsed Timed Comfort Cam shift Binary shift Multiturn cam Time timed Reference Multiturn timed |
MCX_CamSwitchSimple_c MCX_CamSwitchSimple_dc MCX_PulseSwitch_dc MCX_CamSwitchTimed_dc MCX_CamSwitchComfort_dc MCX_CamShift_dc MCX_BinaryShift_dc MCX_CamSwitchMulti_dc MCX_SwitchTimeTimed_dc MCX_BinaryReference_dc MCX_CamSwitchMultiTimed_dc |
0 1 2 3 4 5 6 7 8 9 |
BYTE |
1) camType additionally to camToTrack identifies the type of each cam switch and enables the use of a specific Function Block from the Extended Cam Switch Library.
2) camType parameters and the Extended Camswitch Library: Extended Camswitch Library