Returning a License

Attention

After returning a AC500 runtime license, the PLC system moves into ‘Stop’ mode after 24 h.

Returning a license without SD memory card

A license which has been installed on a PLC device can be returned and installed on another PLC device.

Prerequisites:

  1. Right-click on the PLC node and select Return active license from the Runtime Licensing menu.

    A wizard is started. Follow the instructions.

  2. Enter the license activation key and click Return license.

    The results of the return process will be displayed in the dialog.

    The license from the PLC device is removed and can be used now for another PLC device.

Returning a license via SD memory card

When the PLC is not connected to the PC (PLC logged out) it is possible to return a license via SD memory card.

  1. Place the SD memory card into the PC.

  2. Right-click on the PLC node and select Return active license from the Runtime Licensing menu.

    A wizard is started. Follow the instructions.

  3. Enter the license activation key and click Return license.

    ../_images/506a0662c86fdfcf0a317f3426615105
  4. Click Browse and select the root folder of the SD memory card.

    Returning of the license is started.

  5. Place the SD memory card in the PLC device and reboot the PLC.

    The license from the PLC device is removed and can be used now for another PLC device.

  6. To complete the licensing process, a license receipt file must be uploaded to the ABB license server.

    Save the license receipt file and upload it manually from a PC with internet connection to http://lc.codemeter.com/32838/depot/index.php

    A license confirmation is returned.