Technical Data¶
The System Data of AC500 and S500 are valid for standard version System Data AC500.
The System Data of AC500-XC are valid for the XC version System Data AC500-XC.
Only additional details are therefore documented below.
Communication module CM592-DP | |
---|---|
Field bus | PROFIBUS® DP Master V0 / V1 |
Transmission rate | 9.6 kBit/s to 12 MBit/s |
Field bus connector | D-SUB, 9-pole, female |
Technology | Hilscher netX100 |
Indicators | 5 LEDs |
Usable CPUs | PM57x, PM58x, PM59x PM57x (-y), PM58x (-y) and PM59x (-y) |
Usable Terminal Bases | All TB5xx TB51x-TB54x |
Ingress protection | IP20 |
Current consumption from 24 V DC power supply at the Terminal Base of the CPU | Typ. 150 mA |
Internal power supply | Through the Communication Module interface of the Terminal Base |
Number of IO Devices | Max. 125 |
Quantity of input and output data per IO Device | 244 byte (respectively for input and output) |
Total quantity of input and output data | Max. 4096 byte (respectively for input and output) |
Bus configuration | Done with Automation Builder |
Weight | Ca. 150 g |
Processor | Hilscher netX100 |
Current consumption from 24 VDC power supply at the Terminal Base of the CPU | Typ. 150 mA |
Internal RAM memory | 8 MB |
External Flash memory | 8 MB |
Technical Data of the Interface
Interface socket | 9-pole, SUB-D socket |
Transmission standard | EIA RS-485 acc. to EN 50170, potential-free |
Transmission protocol | PROFIBUS® DP, 12 Mbaud max. |
Transmission rate | Baudrate 9.6 kbit/s up to 12.000 kbit/s |
Status indication | By 5 LEDs |
Number of subscribers (master/slave modules per bus segment) |
32 max. |
Number of subscribers via repeaters | 126 max. |