Technical Data¶
The System Data of AC500 and S500 System Data AC500are valid for standard version.
The System Data of AC500-XC System Data AC500-XCare valid for the XC version.
Only additional details are therefore documented below.
General data of the Processor Modules
For more information, please refer to the AC500 System Data System Data AC500chapter.
Connection of the supply voltage 24 V DC at the removable terminal block of the Processor Module | at a 5-pole removable terminal block with spring connection | |
Current consumption from 24 V DC | 0.4 A | |
Inrush current at 24 V DC | 1 A²s *) | |
Max. power dissipation within the module | 15 W | |
Slots for Communication Modules | 2 | |
Processing Module’s interfaces | I/O-Bus, COM1, COM2 | |
Processing Module’s network interfaces | ETH1 and ETH2 for Ethernet-based system communication ETH3.1 and ETH3.2 for Ethernet-based fieldbusses with switch functionality ETH4.1 and ETH4.2 for Ethernet-based fieldbusses with switch functionality |
|
Connection system | see System Assembly chapter AC500 (Standard) | |
Dimensions | see System Assembly chapter Mechanical Dimensions AC500 | |
Width x height x depth | 230 x 152 x 87 mm | |
Weight | 1070 g | |
Mounting position | horizontal or vertical with derating (50 % output load, reduction of temperature to 40 °C) |
*1) The melting integral for the Processor Module is depending on the integrated Processing Module power supply, number and type of Communication Modules and I/O modules connected to the I/O-Bus.
Detailed data
Parameter | Value | |
---|---|---|
Flash memory for boot projects, symbols and web pages | 32768 kB | |
SDRAM for user program | 16384 kB | |
SDRAM for user data | 16384 kB | |
Expandable memory | None | |
Integrated mass storage memory | 4 GB non rotating flashdisk | |
Pluggable SD Memory Card for: | x | |
User data storage | ||
Program source code storage | ||
Firmware update | ||
Cycle time for 1 instruction | ||
Binary | Min. 0.0006 µs | |
Word | Min. 0.001 µs | |
Floating point | Min. 0.001 µs | |
Max. number of central inputs and outputs (10 exp. modules): | ||
Digital inputs | 320 | |
Digital outputs | 240 | |
Analog inputs | 160 | |
Analog outputs | 160 | |
Number of decentralized inputs and outputs | Depends on the used field bus (as an info on the CS31 Bus: up to 31 stations with up to 120 DI / 120 DO each) | |
Data backup | Battery for PM595-4ETH-F, MRAM for PM595-4ETH-M-XC without battery |
|
Data buffering time at 25 °C | About 3 years | |
Battery low indication | Warning indication issued about 2 weeks before the battery charge becomes critical | |
Real-time clock | ||
With battery back-up | x | |
Accuracy | Typ. ± 2 s / day at 25 °C | |
Integrated Communication Module, ETH = Ethernet RJ45 |
2x Ethernet, 2x Ethernet interfaces with downloadable protocol e.g. PROFINET IO, ETherCAT (in preparation) |
|
Number of external Communication Modules | Up to 2 Communication Modules like PROFIBUS® DP, Ethernet, CANopen® or Safety Module SM560-S. There is no restriction concerning the Communication Module types and Communication Module combinations (e.g. up to 2 PROFIBUS® DP Communication Modules are possible) | |
LEDs | 5 to display statuses, rest of LEDs reserved | |
LCD display | Optional | |
Buttons and switches | 1 button for Reset (Reserved) 1 Button (Reserved) 1 Switch for RUN/STOP |
|
Certifications | CE, GL, DNV, BV, RINA, LRS, cUL |
Ordering Data
Order No. | Scope of Delivery |
---|---|
1SAP 155 500 R0279 | PM595-4ETH-F Processor Module, User Progr./Data memory 16 MB / 16 MB, 1.3 GHz, 24 V DC, Memory Card Slot, interfaces 2x RS232-485, 2x independent Ethernet interfaces (Progr., Webserver, IEC60870-5-104 protocol), 2x independent Ethernet based interfaces with 2-port switch (for downloadable fieldbus protocols e.g. PROFINET IO) |
1SAP 351 500 R0279 | PM595-4ETH-M-XC Processor Module, User Progr./Data memory 16 MB / 16 MB, 1.0 GHz, 24 V DC, Memory Card Slot, interfaces 2x RS232-485, 2x independent Ethernet interfaces (Progr., Webserver, IEC60870-5-104 protocol), 2x independent Ethernet based interfaces with 2-port switch (for downloadable fieldbus protocols e.g. PROFINET IO) for extreme condition environments |
Order No. | Scope of Delivery |
---|---|
Accessories | |
1SAP 182 700 R0001 | TA541 Lithium Battery |
1SAP 180 100 R0001 | MC502, SD Memory Card |
1SAP 180 200 R0001 | TK501, Programming cable SUB-D / SUB-D, length: 5 m |
1SAP 180 200 R0101 | TK502, Programming cable terminal block / SUB-D, length: 5 m |
1TNE 968 901 R1100 | TK503, Programming cable USB / SUB-D (RS-485), length 3 m |
1SAP 182 300 R0001 | TA535 Protective Caps for XC Devices |
1SAP 182 600 R0001 | TA540, Front cover as spare part (3 pieces) |
1SAP 182 800 R0001 | TA543, Screw mounting accessory (20 pieces) |