Input DescriptionΒΆ

Using the Function Block CAN2A_INFO, various status information about the CAN 2.0A communication can be read.

../_images/91abdd1ce3899be70a33139000eba54e

The Function Block CAN2A_INFO outputs information concerning the status of the CAN 2.0A communication.

SLOT

Data_Type Default_Value Range Unit
BYTE - - -

At input SLOT, the Communication Module slot (module number) is selected to used by the Function Block.

The internal Communication Module always has the module number 0. All external Communication Modules are serially numbered from right to left, starting with module number 1.

EN

Data_Type Default_Value Range Unit
BOOL - - -

The Function Block is activated (EN = TRUE) or deactivated (EN = FALSE) via input EN. If the Function Block is active, the current values are available at the outputs. If the Function Block detects a CAN Communication Module with a configured CAN 2.0A protocol at the specified SLOT, this is indicated by DONE = TRUE and ERR = FALSE. The corresponding status information is then available at the Function Block outputs.