Installation of the Files for the CM574-RS

Installation with Control Builder PS501, Version \ V1.3.0 or Higher

From PS501 Control Builder version V1.3.0, all files required for operation of the CM574-RS are installed automatically during installation of the Control Builder.

All files are stored in the AC500 target directory:

..\%CommonProgramFiles%\CAA-Targets\ABB_AC500

The environment variable %CommonProgramFiles% corresponds to

- “Program Files\Common Files” for English operating systems or

- “Programme\Gemeinsame Dateien” for German operating systems.

Installation without Installation of the Control Builder \ PS501

The target for the CM574-RS can also be carried out without installing the PS501 Control Builder version V1.3.0 (or higher). If for example version V1.2.x of the PS501 Control Builder is installed on the PC, the target can be installed separately to it.

The procedure for installing a target is described in detail in “System Technology CPUs” Installation of the AC500 targets with the program InstallTarget ” Target Support Package.

The file AC500_CM574_V13.tnf has to be selected.

Caution

In order to be able to use the target of the CM574-RS, it is imperative that the AC500 targets of version V1.2 are installed, as for example all libraries are loaded from the directory of the V1.2 targets.

Overview of Files belonging to the Target CM574-RS

The AC500 targets of version V1.3.x have the following file structure:

../_images/2d5b4e31e38c10f60a33139000eba54e

The target of the CM574-RS includes the following files:

No. Directory / File Description
..\%CommonProgramFiles%\CAA-Targets\ABB_AC500
1 AC500_CM574_V13.trg Target system settings
..\%CommonProgramFiles%\CAA-Targets\ABB_AC500\AC500_CM574
2 TaskConfig_CM574.xml Task configuration settings
..\%CommonProgramFiles%\CAA-Targets\ABB_AC500\AC500_CM574\PLCConf   see note 1)
3 AC500_CM574_CPU_V13.cfg Configuration file CM574 ““ CPU
4 AC500_CM574_COMx_V13.cfg Configuration file for COMx of the CM574
5 AC500_DPR_CPU_Comm_V13.cfg Configuration file for I/O data exchange DPR/CPU (see note 2)
6 AC500_CS31Base_V10.cfg Configuration file CS31 bus / DC551
7 AC500_ModCS31_V10.cfg Configuration file AC31 modules for CS31 bus
8 AC500_IOclass_V12.cfg Configuration file for S500 I/O modules
9 AC500_IOmodule_V10.cfg Configuration file for S500 I/O modules of V1.0
10 AC500_IOmod2_V11.cfg Configuration file for new S500 I/O modules from V1.1
11 AC500_IOCD522_V13.cfg Configuration file for S500 I/O module CD522
12 AC500_IOAI531_V13.cfg Configuration file for S500 I/O module AI531
13 AC500N_IOmod_V13.cfg Configuration file for new S500 I/O modules from V1.3
11 ChanIn.ico Icon for PLC configuration
12 ChanInOut.ico  
13 ChanOut.ico  
14 COMio.ico  
15 COMonl.ico  
16 COMx.ico  
17 Communication Module.ico  
18 ModIn.ico  
19 ModInOut.ico  
20 ModOut.ico  
21 DC51x.ico  
22 DC505.ico  
23 ICMK.ico  
24 S50exp.ico  
25 S90io.ico  
26 S500.ico  
27 S500exp.ico  
..\%CommonProgramFiles%\CAA-Targets\ABB_AC500\AC500_V12\PLCConf
28 AC500_CM574_V13.cfg Configuration file CM574 in AC500 CPU
29 AC500_DPR_CPU_Comm_V13.cfg Configuration file for I/O data exchange DPR/CPU (see note 2)
..\%CommonProgramFiles%\CAA-Targets\ABB_AC500\AC500_V12\Library
30 SysIntExt_AC500_V13.lib Extended system library for AC500

Overview of Files belonging to the Target CM574-RS

  1. The actual number of configuration files can differ from that in the table. For example, configuration files of additional S500 I/O devices can be added.
  2. The configuration file AC500_DPR_CPU_Comm_V13.cfg is the same file for the CM574 Communication Module and the AC500 CPU.