Power Supply
The supply voltage of 24 V DC is connected to a 5-pole removable terminal block. ZP and UP exist twice. So it is possible to supply external sensors (up to 8 A max.) from these terminals, for instance.
Terminal block removed |
Terminal block inserted |
L+ | +24 V DC | UP | |
L+ | +24 V DC | UP | |||
M | 0 V | ZP | |||
M | 0 V | ZP | |||
FE | FE | Functional Earth | |||
1 | Terminator P | RS-485 | Terminator P | ||
2 | RxD/TxD-P | RS-485 | Receive/Transmit, positive | ||
3 | Rxd/TxD-N | RS-485 | Receive/Transmit, negative | ||
4 | Terminator N | RS-485 | Terminator N | ||
5 | RTS | RS-232 | Request to send (output) | ||
6 | TxD | RS-232 | Transmit data (output) | ||
7 | SGND | Signal Ground | |||
8 | RxD | RS-232 | Receive data (input) | ||
9 | CTS | RS-232 | Clear to send (input) |