PROFINET IO Controller - GeneralΒΆ

Object: PROFINET IO controller

The PROFINET IO controller, like the slaves, is identified by the station name. For AC500 Communication Modules, you can also configure the IP settings here. Otherwise the settings apply from the superordinate Ethernet node.

Station name The station name of the device. It is used for unique identification of the device in the network.
:guilabel:`IP Parameters`\
IP address

Please note: Available for AC500 Communication Modules only.

If you insert the controller below an Ethernet adapter, you must define the IP parameters in the dialog of the Ethernet adapter.

Subnet mask
Default gateway
:guilabel:`Default Slave IP Parameters`\  
First IP address Range of IP addresses that CODESYS uses by default when inserting PROFINET IO devices into the device tree. If you use the Auto IP function (command Set IP) in the scan dialog, then IP addresses are also used from this range. Then the next free IP address is selected.
Last IP address
Subnet mask
Default gateway
:guilabel:`Watchdog`\ Please note: Available for AC500 Communication Modules only.
enable

b9d5ea51e1b592bdc0a8640e005e0b0d_9a3f06830c0506c5c0a8640e012f0ace : If the AC500 Communication Module firmware is not set within the given time (for example, in the case of an exception error in the application), then it is reset. The connection is terminated and the slaves switch to their substitute values.

The presets for the watchdog are from the device description.