ACS_COM_MOD_RTU_GEN_WRITE_N_PRM_VISU_PH Visualization Faceplate for the Function Block ACS_COM_MOD_RTU_GEN_WRITE_N_PRM\ΒΆ

../_images/5c88062c48bf05290a331390019d303e
../_images/20b96b6d48bf06800a3313900146ae54

Visualization offline / online mode

Visualization element ACS_COM_MOD_RTU_GEN_WRITE_N_PRM_VISU_PH can be used to show the actual values of all inputs and outputs of the instance of an ACS_COM_MOD_RTU_GEN_WRITE_N_PRM ACS_COM_MOD_RTU_GEN_WRITE_N_PRM Write N Parameters to a Generic MODBUS RTU Device Function Block which instance was used to replace the placeholder $FB$.

The visualization can also be used to control the Function Block by those inputs which are not connected inside the program.

Visualization Data

Available as of PLC runtime system: V1.3.2
Included in library: ACSDrivesComModRTU_AC500_V20.lib

Description

Visualization element ACS_COM_MOD_RTU_GEN_WRITE_N_PRM_VISU_PH can be used to show the actual values of all inputs and outputs of the instance of an ACS_COM_MOD_RTU_GEN_WRITE_N_PRM Function Block which instance was used to replace the placeholder $FB$.

All inputs of that ACS_COM_MOD_RTU_GEN_WRITE_N_PRM Function Block which are not connected to a variable (left open) can be written from this visualization faceplate. So the Function Block can be controlled from the visualization as long as the inputs are left open.

The SLAVE_DATA variable must be connected to the Function Block.

The values to be written can not be displayed with this visualization faceplate, because they have to be accessed by the ADR operator outside the Function Block ACS_COM_MOD_RTU_GEN_WRITE_N_PRM.

../_images/9c6bf64948bee2bb0a33139001fa2e80
../_images/ebd017e348bee4310a33139000e76358