Output Description¶
DONE
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
BOOL | - | - | - |
DONE indicates the processing state of the function block. After completion or abortion of processing due to an error, DONE is set to TRUE for one cycle. This output always has to be considered together with output ERR. If ERR is TRUE, an error occurred. In this case, the error number can be read at output ERNO.
ERR (error)
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
BOOL | - | - | - |
ERR indicates whether an error occurred during the processing of the function block. This output always has to be considered together with output DONE. If DONE is TRUE and ERR is TRUE, an error occurred. In this case, the error number can be read at output ERNO.
ERNO
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
WORD | - | 0 … 65535 | - |
At output ERNO the identifier of an occurred error is provided. It is only valid when DONE and ERR is TRUE, (see, error messages): Error Messages of the Function Block Libraries
RDY_REF (ready reference)
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
BOOL | - | - | - |
RDY_REF displays the ready message of the reference point approach.
RDY_TOUCH (ready message touch trigger)
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
BOOL | - | - | - |
RDY_TOUCH displays the ready message of the touch trigger measurement.
MAX_LIM (maximum \ limit)
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
BOOL | - | - | - |
In the infinite counter operating mode (endless mode), MAX_LIM indicates whether the actual counter value is higher than the value set at input LIM_MAX.
In the limiting counter operating mode (limit mode), output MAX_LIM is FALSE.
MIN_LIM (minimum \ limit)
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
BOOL | - | - | - |
In the infinite counter operating mode (endless mode), output MIN_LIM indicates whether the actual counter value is lower than the value set at input LIM_MIN.
In the limiting counter operating mode (limit mode), output MIN_LIM is FALSE.
CNT_ACT (counter actual)
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
DWORD | - | - | - |
CNT_ACT displays the actual counter value of the count-up counter.
CNT_TOUCH (counter touch trigger)
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
DWORD | - | - | - |
Output CNT_TOUCH displays the result of the touch trigger measurement, i.e. the actual counter value at the moment of the occurrence of the rising edge at input C2 after initiation of a touch trigger measurement by a rising edge at input EN_TOUCH.