Input DescriptionΒΆ
EN
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
BOOL | - | - | - |
The Function Block is activated (EN = TRUE) or deactivated (EN = FALSE) via input EN. If the Function Block is active, the current values are available at the outputs.
ID
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
BYTE | - | - | - |
At input ID, the value of the FlexConfID which should be written to the configuration data has to be has to be specified.
REBOOT
Data_Type | Default_Value | Range | Unit |
---|---|---|---|
BOOL | - | - | - |
If this input is set to TRUE, the PLC will be rebooted after the FlexConfID has been written. If this input is set to FALSE, the PLC will not be rebooted. In this case, the currently configuration stays active until the CPU will be rebooted manually.