Input Description¶
EN
| Data_Type | Default_Value | Range | Unit |
|---|---|---|---|
| BOOL | FALSE | TRUE/FALSE | - |
The input EN has to be driven in edge triggered mode.
The execution of the Function Block is started with a positive edge on the input EN.
In the first call it evaluates its inputs and creates a local copy of them. Afterwards it starts its internal algorithm. It may take several PLC task cycles until it is executed.
Once the execution is completed DONE and its other outputs are set. To start the Function Block again a new positive edge on the input EN has to be applied.
SLOT
| Data_Type | Default_Value | Range | Unit |
|---|---|---|---|
| BYTE | 0 | 0 … 4 (6) | - |
At input SLOT, the Communication Module slot is specified which should be used by the Function Block.
The internal Communication Module always has the index 0. All external Communication Modules are serially numbered from right to left, starting with 1.
NODE
| Data_Type | Default_Value | Range | Unit |
|---|---|---|---|
| WORD | - | - | - |
Input NODE specifies the number of the slave. The value 255 sets all slaves to the same time (all slaves are called).
HOUR_SET
| Data_Type | Default_Value | Range | Unit |
|---|---|---|---|
| WORD | - | - | - |
Input HOUR_SET specifies the value of the hour component of the time.
MIN_SET
| Data_Type | Default_Value | Range | Unit |
|---|---|---|---|
| WORD | - | - | - |
Input MIN_SET specifies the value of the minutes component of the time.
SEC_SET
| Data_Type | Default_Value | Range | Unit |
|---|---|---|---|
| WORD | - | - | - |
Input SEC_SET specifies the value of the seconds component of the time.