TECT_DATA_FLASH_VISU_PH¶
Description
Visualization element TECT_DATA_FLASH_VISU_PH is used to show the actual values of all inputs and outputs of the instance of TECT_DATA_FLASH_VISU_PH. The visualization is also used to control the Function Block by those inputs, which are not connected inside the program. The figures show the visualization in offline and online mode.
TECT_DATA_FLASH_VISU_PH template in offline mode
TECT_DATA_FLASH_VISU_PH template in online mode
Colors
The color of the variables has the following meaning:
- WHITE: Actual FALSE and should be FALSE in normal operation
- GREEN: Actual TRUE and should be TRUE in normal operation
- YELLOW: Actual FALSE, but should be TRUE in normal operation
- RED: Actual TRUE, but should be FALSE in normal operation
Visualization Parameters
Variable Element | Access | Way of Access | Description (all elements refer to the Function Block instance, replaced for the placeholder $FB$) |
---|---|---|---|
EN | R/W | Toggle | Enable Function Block by TRUE level at input EN |
OPERATION | R/W | Numpad | Operation type := 1: READ, 2: WRITE. |
FLASH_SEGMENT | R/W | Numpad | Number of the data segment; 1 or 2 |
FIRST_FLASH_BLOCK | R/W | Numpad | Number of the flash block within the data segment: 0…1926 |
NUM_OF_ZONE | R/W | Numpad | Number of zones in the system to be operated |
DONE | R | Execution finished, when output DONE = TRUE | |
ERR | R | Error occured during execution when output ERR = TRUE | |
ERNO | R | Error Codes | |
BUSY | R | Recipe operation busy |
All inputs of TECT_DATA_FLASH Function Block, which are not connected to a variable (left open), can be written from this visualization faceplate. The Function Block can be controlled from the visualization as long as the inputs are left open.
The color of the background can be changed by writing a value to the global variable dwTectControlVisuBackgroundColor. The color of the title can be changed by writing a value to the global variable dwTectControlVisuTitleColor.