Input Description

../_images/bcbfd47ee389c8b10a33139000eba54e

SLOT

Data_Type Default_Value Range Unit
BYTE - - -

Reserved for future extensions.

COM

Data_Type Default_Value Range Unit
BYTE - - -

Communication Port to which the CS31 Bus Module is connected.

MODULE_ADR

Data_Type Default_Value Range Unit
BYTE - 0 … 99 -

Address of the CS31 Bus Module from which the firmware versions should be readout.

EN

Data_Type Default_Value Range Unit
BOOL - - -

The Function Block is activated with a value transition from FALSE->TRUE at the variable EN. Otherwise it remains disabled.

If the Function Block is activated the specified input values are used and the output values are available at the Function Block outputs.

EN_VISU

Data_Type Default_Value Range Unit
BOOL - - -

If input EN_VISU = TRUE, it is also possible to control the Function Block inputs (except EN and EN_VISU) via the integrated visualization of the Function Block. If input EN_VISU = FALSE, control via the visualization is disabled. The actual values are always displayed.