Error Messages, Warnings and Notes (Dialogs)¶
Wrong Target
This error message appears if there is a mismatch between the selected target in Automation_Builder and the CPU hardware. For example, the selected CPU type is PM583-ETH and in Automation_Builder project, the configured CPU type is PM573-ETH.
A login to the CPU is not possible.
To avoid this error message, correct the project to the appropriate CPU target.
Configuration not yet in PLC
Note
The following warning message will only appear with CPU firmware V2.3.0 or higher.
This warning message appears if the current project in Automation_Builder and the project located inside the PLC are different.
To avoid this warning message, perform the following tasks:
- Log out from the PLC.
- Re-create configuration data (right-click on ).
- Download the IEC application program to the PLC via IEC 61131-3 editor V2.3.x (a full download is needed).
- Log in for Online Diagnosis again.
Old Profile in Firmware
Note
The following warning message will only appear with CPU firmware V2.3.0 or higher.
This warning messages appears, if the firmware version inside the PLC is older than the version profile of Automation_Builder and therefore, the CPU’s firmware does not support all features of the current version profile of Automation_Builder.
To avoid this warning message, perform one of the following tasks:
- Update the CPU’s firmware to the version which is equivalent to the Automation_Builder version profile.
- Select a version profile in Automation_Builder which is equivalent to the firmware version of the CPU.