Bipolar Voltage Input Range, Measuring \ Bridge

Range -50 … +50 mV -500 … +500 mV -1 … +1 V -5 … +5 V -10 … +10 V Common Mode Voltage Digital value
              Decimal Hex.
Overflow > 58.7945 > 587.9949 > 1.17589 > 5.8794 > 11.7589 > 20.0000 32767 7FFF
Measured value too high

58.7945

:

50.0018

587.9449

:

500.0181

1.17589

:

1.00004

5.8794

:

5.0002

11.7589

:

10.0004

 

32511

:

27649

7EFF

:

6C01

Normal range

Normal range or Measured value too low

50.0000

:

0.0018

500.0000

:

0.0181

1.00000

:

0.00004

5.0000

:

0.0002

10.0000

:

0.0004

20.0000

:

0.0008

27648

:

1

6C00

:

0001

0.0000 0.0000 0.0000 0.00000 0.0000 0.0000 0 0000

-0.0018

:

-50.0000

-0.0181

:

-500,0000

-0.00004

:

-1,00000

-0.0002

:

-5,0000

-0.004

:

-10,0000

-0.0008

:

-20.0000

-1

:

-27648

FFFF

:

9400

Measured value too low

-50,0018

:

-58.7945

-500.0181

:

-587.9449

-1.00004

:

-1.17589

-5.0002

:

-5.8794

-10.0004

:

-11.7589

 

-27649

:

-32512

93FF

:

8100

Underflow < -58.7945 < -587.9949 < -1.17589 < -5.8794 < -11.7589 < -20.0000 -32768 8000

The represented resolution corresponds to 16 bits.