Parameterization

Firmware version Configuration
Firmware version > V2.0.0 The arrangement of the parameter data is performed by Control Builder Plus/ Automation_Builder software.

The parameter data directly influences the functionality of modules.

For non-standard applications, it is necessary to adapt the parameters to your system configuration.

Module: Module slot address: Y = 1…10

Name Value Internal Value Internal value, Type Default Min. Max. EDS Slot Index
Module ID Intern 1805 *1) WORD 0x070D 0 65535 0x0Y01
Ignore module *2)

No

Yes

0

1

BYTE

No

0x00

    Not for FBP
Parameter length Internal 42 BYTE 0 0 255 xx02 *3)
Check supply

Off

On

0

1

BYTE

On

0x01

    0x0Y03
Input delay

0.1 ms

1 ms

8 ms

32 ms

0

1

2

3

BYTE

8 ms

0x02

0 3 0x0Y04
Mode Counter 0 see table below 0 BYTE 0x00 0 15 0x0Y05
Counter 0 frequency limit

No filter

50 Hz

500 Hz

5 kHz

20 kHz

0

1

2

3

4

BYTE

No filter

0x00

0 4 0x0Y06
Counter 0 input level

0-24 V DC

0-5 V DC

Differential

1 Vpp sinus

0

1

2

3

BYTE 0-24 V DC 0x00 0 3 0X0Y07
SSI 0 frequency

200 kHz

500 kHz

1 MHz

2

3

4

BYTE

200 kHz

0x02

0 4 0x0Y08
SSI 0 resolution (in bit) 8 to 32 bit   BYTE

16 bit

16

8 32 0x0Y09
SSI 0 code type Binary 0 BYTE

Binary

0

0 0 0x0Y0A
SSI 0 polling time 10 ms   BYTE 10 1 255 0x0Y0B
5 V sensor 0 supply

Off

On

0 BYTE

Off

0x00

0 1 0x0Y0C
Mode Counter 1 see table below 0 BYTE 0x00 0 15 0x0Y0D
Counter 1 frequency limit

No filter

50 Hz

500 Hz

5 kHz

20 kHz

0

1

2

3

4

BYTE

No filter

0x00

0 4 0x0Y0E
Counter 1 input level

0-24 V DC

0-5 V DC

Differential

1 Vpp sinus

0

1

2

3

BYTE 0-24 V DC 0x00 0 3 0X0Y0F
SSI 1 frequency

200 kHz

500 kHz

1 MHz

2

3

4

BYTE

200 kHz

0x02

2 4 0x0Y10
SSI 1 resolution (in bit) 8 to 32 bit   BYTE

16 bit

16

8 32 0x0Y11
SSI 1 code type Binary 0 BYTE

Binary

0

0 0 0x0Y12
SSI 1 polling time 10 ms   BYTE 10 1 255 0x0Y13
5 V sensor 1 supply

Off

On

0 BYTE

Off

0x00

0 1 0x0Y14
Detection SC on sensors

Off

On

0 BYTE

Off

0x00

0 1 0x0Y15
Output behaviour com fault

Off

Last value

Substitute

Last value 5s

Substitute 5s

Last value 10s Substitute 10s

0

1

2

3

4

5

6

BYTE

Off

0x00

0 1 0x0Y16
Substitute value 0 0 WORD

Default

0x0000

0 65536 0x0Y17

*1) With CS31 and addresses smaller than 70 and FBP, the value is increased by 1

*2) Not with FBP

*3) Value is hexadecimal: HighByte is slot (xx: 1 … 10), LowByte is index (1 … n)

Operating modes for counters 0 and 1, configuration \ table
Internal value Operating modes of counter
0 No counter / No PWM (default value)
1 1-1 UpDown counter (A)
2 2-1 UpDown with release input
3 3-2 UpDown counters (A, B)
4 4-2 UpDown (A, B on falling edges)
5 5-1 UpDown dynamic set (B) / rising edge
6 6-1 UpDown dynamic set (B) / falling edge
7 Not used
8 8-1 UpDown with release (B), 0 cross detection
9 - 19 Not used
20 11-1 Incremental encoder
21 12-2 Incremental encoder X2
22 13-1 Incremental encoder X4
30 14-1 SSI, absolute encoder
40 15-1 Time frequency meter
GSD file

Ext_User_Prm_Data_Len =

Ext_User_Prm_Data_Const(0) =

25

0x07, 0x0E, 0x17, \

0x01, 0x02, \

0x00, 0x00, 0x00, 0x02, 0x10, 0x00, 0x0A, 0x00, \

0x00, 0x00, 0x00, 0x02, 0x10, 0x00, 0x0A, 0x00, \

0x00, 0x00, 0x00, 0x00;