Communication Module Configuration (Communication \ Modules)

Note

AC500 PM55x and PM56x CPUs do not have a Communication Module interface.

In the standard configuration selected with “File” / “New” or “Extras” / “Standard configuration”, the PLC configuration contains no Communication Modules:

../_images/37306e68e38c52780a33139000eba54e

PLCconf_Communication Module1.png

The following assignment between Communication Module line and slot applies to the Communication Modules:

  • Line 0 corresponds to the internal Communication Module (installed in the CPU’s housing)
  • Line 1 is the Communication Module installed in the first slot on the left of the CPU
  • Line 2 is the Communication Module installed in the second slot on the left of the CPU
  • Line 3 and 4 are installed in the third and fourth slot on the left of the CPU

The allocation of inputs/outputs for the Communication Modules is done slot-oriented and independent of the Communication Module type.

Note

If a Communication Module slot is empty, the entry “External none” has to be set for this Communication Module slot. This is not necessary, if no external Communication Module is inserted. Example: Internal Ethernet Communication Module and PROFIBUS® Communication Module in slot 2

1. Replace element: “Internal none” by “PM5x1 Internal Ethernet”

2. Append subelement: “External none” to empty slot 1

3. Append subelement: “CM572 External PROFIBUS® DP Master” in slot 2