1000hex…1FFFhex - Device Error

DEC HEX Error description
4097 1001 Device does not exist
4098 1002

Command not supported by the device. The function is not supported by the device firmware/hardware. Block library newer than the device firmware.

FC..: No high-speed counter available at the given module.

4100 1004

Error operating mode.

FC..: Operating mode “0” -> No counter set in the PLC configuration.

4101 1005

Invalid status

FLASH_READ: Block is not written yet

FLASH_WRITE: Block was already written

RETAIN..: No program loaded

Library PROFINET IO: PNIO_WRITE, PNIO_READ: Internal error. Restart the PLC.

4117 1015

Format error

SD..: File cannot be read because of an invalid format. Data could not be read or not be read completely.

4119 1017

Incorrect length

PERSISTENT..: Data have an incorrect length

RETAIN..: Data have an incorrect length

4120 1018 Checksum error
4122 101A

FC..: Internal error (e.g. no CS31 Adr parameter found, wrong size of CS31 Adr)

HA..: Internal error (e.g. null pointer received, wrong return value of internal function, no entry in configuration found)

4123 101B

Device access error

Flash..: Resources are not available

HA..: Remote CPU failure: Other CPU is off or out of order

PERSISTENT..: Data could not be copied, access error or no data do exist

RETAIN..: Data could not be copied, access error or no data do exist

SD..: Access to the SD card is not possible (e.g. memory exhausted, file already opened, etc.

4124 101C

Incorrect number

PERSISTENT..: Because of the current CPU parameters, data are loaded only partly

4127 101F

Access protection

SD..: SD card is write protected

4128 1020

Error when opening

SD..: Error when opening a file stored on the SD card

4129 1021

Not found

FC..: CS31 Bus Module not found

ETHERCAT Modul not found

HA_CS31_CONTROL: Own CI590-CS31-HA slave failure (missing module)

HA_CS31_DIAG: One or more CI590-CS31-HA slave(s) is/are inactive

HA_CS31_DIAG_VIA_CM574-RS: One or more CI590 are inactive

SD..: The searched sector could not be found in the file

TASK_INFO: Unknown task

4130 1022

End reached

SD..: Section end or end of file reached

PERSISTENT..: Because of the current CPU parameters, data are not loaded

4131 1023

Reading error

FLASH..: Reading error in data segment: Incorrect checksum

4132 1024

Writing error

FLASH..: Block cannot be programmed

SD..: File could not be deleted or written

4137 1029

FC..: Wrong configuration (e.g. no CM574-RS configured on specified slot)

HA..: Remote CI590-CS31-HA slave failure (missing module)

8191 1FFF

Not ready

Flash..: The command is already executed by an other instance

SD..: Command cannot be executed. Another instance is already active.