Input DescriptionΒΆ

../_images/c13cb325b45cb85f0a3313900118ae03

Function Block CMC_MOTION_KERNEL_INT

Note

The inputs marked with a triangle b312f91ab44cbd6f0a33139001f44529_78f228175b765b440a33139001315693 are of the class VAR_IN_OUT (input and output variable). These inputs must be connected to a variable.

ENABLE

Data type: BOOL

Release of Function Block. Enable has to be set before new control parameters are released by CMC_AXIS_CONTROL_PARAMETER.

DRIVE_REF_OK

Data type: BOOL

Indication for homing.

DRIVE_INOPERATION

Data type: BOOL

Indication that drive is running.

DRIVE_ACTUALPOSITION

Data type: DINT

Actual position in increments.

Axis

Data type: AXIS_REF

Reference to the axis.

CONTROL_PARAMETER

Data type: CMC_AXIS_CONTROL_PARAMETER

Parameters for configuration and adjustment of the control loop. Central Motion Control (PLC-Based)

IO

Data type: CMC_AXIS_IO

By the structure IO (CMC_AXIS_IO), some binary inputs are provided. The PLC program has to define a variable of type CMC_AXIS_IO and to assign the inputs.