ONB_IO_INT_IN

../_images/2e868859e38acae30a33139000eba54e
Parameter Value
Library_File_Name OnBoardIO_AC500_V13.lib
Firmware V1.3.0
Type Type_Function_Block_History
Group Interrupt_Input_OBIO

Using the Function Block ONB_IO_INT_IN, the interrupt program can be polled which inputs (IN0…IN3) triggered interrupts since the last Function Block calling. The corresponding outputs IN0…IN3 are set to TRUE.