Output DescriptionΒΆ
Function Block MC_CamIn
InSync
Data type: BOOL
Cam is engaged for the first time.
Busy
Data type: BOOL
The Function Block is not finished.
Active
Data type: BOOL
Indicates that the Function Block has control on the axis.
CommandAborted
Data type: BOOL
Command is aborted by another command (PLCopen Function Block).
Error
Data type: BOOL
Signals that an error has occurred within the Function Block.
ErrorID
Data type: WORD
Error identification PLCopen.
EndOfProfile
Data type: BOOL
Pulsed output signaling the cyclic end of the CAM Profile.