Digital/Analog Input/Output Module DA502ΒΆ
- 16 digital outputs 24 V DC
- 8 configurable digital inputs/outputs 24 V DC
- 4 analog inputs (resolution 12 bits plus sign)
- 2 analog outputs (resolution 12 bits plus sign)
- Fast Counter
- Module-wise electrically isolated
- XC version for usage in extreme ambient conditions available
Overview: Digital/Analog Input/Output Module DA502, plugged on a Terminal Unit TU516
| Elements of the module | |
|---|---|
| 1 | I/O-Bus |
| 2 | Allocation between terminal No. and signal name |
| 3 | 16 yellow LEDs to display the signal statuses of the digital outputs DO0 to DO15 |
| 4 | 4 yellow LEDs to display the signal statuses of the analog inputs AI0 to AI3 |
| 5 | 2 yellow LEDs to display the signal statuses of the analog outputs AO0 to AO1 |
| 6 | 8 yellow LEDs to display the signal status of the configurable digital inputs/outputs DC16 to DC23 |
| 7 | 1 green LED to display the process voltage UP |
| 8 | 4 red LEDs to display errors |
| 9 | Label |
| 10 | I/O Terminal Unit (TU515/TU516) with 40 terminals (screw type or spring terminals) |
| 11 | DIN rail |
| Sign for XC version | |
- Intended Purpose
- Functionality
- Electrical Connection
- Connection of the digital outputs
- Connection of the configurable digital inputs/outputs
- Connection of resistance thermometers in 2-wire configuration to the \ analog inputs
- Connection of resistance thermometers in 3-wire configuration to the \ analog inputs
- Connection of active-type analog sensors (voltage) with electrically \ isolated power supply to the analog inputs
- Connection of active-type analog sensors (current) with electrically \ isolated power supply to the analog inputs
- Connection of active-type analog sensors (voltage) with no electrically \ isolated power supply to the analog inputs
- Connection of passive-type analog sensors (current) to the analog inputs
- Connection of active-type analog sensors (voltage) to differential \ analog inputs
- Use of analog inputs as digital inputs
- Connection of analog output loads (voltage)
- Connection of analog output loads (current)
- Internal Data Exchange
- I/O Configuration
- Parameterization
- Diagnosis
- Displays
- Measuring Ranges
- Technical Data
- Technical Data of the Module
- Technical Data of the Digital \ Outputs
- Technical Data of \ the Configurable Digital Inputs/Outputs
- Technical Data of the Fast Counter
- Technical Data of the Analog Inputs
- Technical data of the \ analog inputs, if they are used as digital inputs
- Technical Data of the Analog \ Outputs
- Ordering Data